Shopping List
Shopping List
Automation & Controls
Auxiliary Contact
Auxiliary Contact
Auxiliary Contact
Rated Current
AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC
DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz
DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz
6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC
DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz
Range
Acti 9
Compact
Tesys
TeSys
Acti 9
Compact
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
IEC 60947-3
IEC 60947-5
EN/IEC 60947-5-1
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
IEC 60947-3
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1
600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14
300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1
500 V
690 V conforming to IEC 60947-1
600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14
IP Degree of Protection
IP20 conforming to IEC 60529
IP2X
IP2X conforming to IEC 60529
IP20 conforming to EN/IEC 60947-5-1
IP20 conforming to IEC 60529
IP2X
Programmable Logic Controllers
Programmable Logic Controllers
Programmable Logic Controllers
Product Or Component Type
Logic controller
Discrete I/O extension module
Modular smart relay
Compact discovery packs
Logic controller
Discrete I/O extension module
Range Of Product
Modicon M251
Modicon M221
Zelio Logic
Modicon M171/M172
Modicon M251
Modicon M221
Standards
IEC 61000-4-12 IEC 60068-2-6 Fc IEC 61000-4-5 IEC 60068-2-27 Ea IEC 61000-4-6 level 3 IEC 61000-4-3 IEC 61000-4-4 level 3 IEC 61000-4-11 IEC 61000-4-2 level 3
IEC 61000-4-2 level 3 IEC 61000-4-12 IEC 61000-4-11 IEC 61000-4-3 IEC 60068-2-6 Fc IEC 61000-4-6 level 3 IEC 60068-2-27 Ea IEC 61000-4-5 IEC 61000-4-4 level 3
CAN/CSA-E60730-1<br />CSA E60730-2-9<br />EN 60068-2-27<br />EN 60068-2-6 Fc<br />EN 60730-1<br />EN 60730-2-9<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-2<br />IEC 61000-4-3<br />IEC 61000-4-4<br />IEC 61000-4-5<br />IEC 61000-4-6<br />IEC 61000-4-11<br />UL94 (material V0)
IEC 61000-4-5<br />IEC 61000-4-3<br />IEC 61000-4-2<br />EN 60068-2-27<br />EN 60730-1<br />EN 60068-2-6 Fc<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-4<br />CAN/CSA-E60730-1<br />IEC 61000-4-11<br />IEC 61000-4-6<br />CSA E60730-2-9<br />EN 60730-2-9<br />UL94 (material V0)
IEC 61000-4-12 IEC 60068-2-6 Fc IEC 61000-4-5 IEC 60068-2-27 Ea IEC 61000-4-6 level 3 IEC 61000-4-3 IEC 61000-4-4 level 3 IEC 61000-4-11 IEC 61000-4-2 level 3
IEC 61000-4-2 level 3 IEC 61000-4-12 IEC 61000-4-11 IEC 61000-4-3 IEC 60068-2-6 Fc IEC 61000-4-6 level 3 IEC 60068-2-27 Ea IEC 61000-4-5 IEC 61000-4-4 level 3
Ambient Air Temperature For Operation
-10…50 °C (vertical installation) -10…55 °C (horizontal installation)
-10…55 °C (horizontal installation) -10…35 °C (vertical installation)
-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…65 °C conforming to UL 60730-1<br />-20…60 °C horizontal conforming to UL 60730-1
-10…50 °C (vertical installation) -10…55 °C (horizontal installation)
-10…55 °C (horizontal installation) -10…35 °C (vertical installation)
Product Certifications
GL C-Tick CSA UL GOST
GOST CSA UL C-Tick GL
DNV-GL EAC ABS cULus LR RCM CE UKCA cULus HazLoc
EAC<br />CE<br />cURus<br />CSA<br />RCM
GL C-Tick CSA UL GOST
GOST CSA UL C-Tick GL
Image
Top