Current
Voltage
Frequency
Power factor
Energy
Active and reactive power
Display Type
Monochrome graphic LCD
Standards
IEC 60529
UL 61010-1
IEC 61557-12:2015
IEC 62053-24
IEC 62053-22:2020
EN 50470-3
EN 50470-1
IEC 62053-23:2020
IEC 62052-11:2020
IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C meter
-20…70 °C display
-25…-20 °C (with reduced performance) display
Width
96 mm
This spec is not available in the specification table.
Device Short Name
PM5341
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM5000
This spec is not available in the specification table.
Depth
72 mm
This spec is not available in the specification table.
Device Application
Power monitoring
Multi-tariff
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Flush-mounted
This spec is not available in the specification table.
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
This spec is not available in the specification table.
Network Frequency
50 Hz
60 Hz
This spec is not available in the specification table.
Sampling rate
64 samples/cycle
This spec is not available in the specification table.
Measurement current
5…8500 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
BACnet IP
This spec is not available in the specification table.
Communication port support
ETHERNET
This spec is not available in the specification table.
Number of inputs
2 digital
This spec is not available in the specification table.
Number of outputs
2 relay
2 digital
This spec is not available in the specification table.
Connections - Terminals
Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
Input/output circuit: screw terminal block6
Relay output: screw terminal block4
Ethernet network: RJ45 connector
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
MID conforming to EN 50470-1
MID conforming to EN 50470-3
This spec is not available in the specification table.
IP Degree of Protection
IP54 display: conforming to IEC 60529
IP30 rear: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C non-condensing
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
2000 m CAT III
3000 m CAT II
This spec is not available in the specification table.
Power quality analysis
up to the 31st harmonic
This spec is not available in the specification table.
supply voltage
90...450 V AC 45...65 Hz
100...300 V DC
This spec is not available in the specification table.
type of network
1P + N
3P + N
3P
This spec is not available in the specification table.
Maximum power consumption in VA
11 VA at 415 V
This spec is not available in the specification table.
Ride-through time
80 ms 120 V AC typical
100 ms 230 V AC typical
100 ms 415 V AC typical
50 ms 125 V DC typical
This spec is not available in the specification table.
Display resolution
128 x 128 pixels
This spec is not available in the specification table.
Analogue input type
Voltage (impedance 10 MOhm)
Current (impedance <= 0.3 mOhm)
This spec is not available in the specification table.
Measurement voltage
35…760 V AC 45...65 Hz between phases
20…400 V AC 45...65 Hz between phase and neutral
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Active energy +/- 0.5 %
Reactive energy +/- 2 %
Active power +/- 0.5 %
Apparent power +/- 0.5 %
Frequency +/- 0.05 %
Power factor +/- 0.5
Current +/- 0.5 %
Voltage +/- 0.5 %
Apparent energy +/- 0.5 %
Reactive power +/- 2 %
This spec is not available in the specification table.
data recording
Alarm logs
Time stamping
Min/max of instantaneous values
Event logs
Maintenance logs
Data logs
This spec is not available in the specification table.
Electromagnetic Compatibility
Limits for harmonic current emissions class A conforming to IEC 61000-3-2
Electrostatic discharge level 4 conforming to IEC 61000-4-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
This spec is not available in the specification table.
Information displayed
Tariff (4)
This spec is not available in the specification table.
memory capacity
256 kB
This spec is not available in the specification table.