This spec is not available in the specification table.
Standards
EN/IEC 60947-4-1
EN/IEC 60947-5-1
EN 45545: R22 HL3
EN 45545: R26 HL3
DIN 5510-2
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947
This spec is not available in the specification table.
Mounting Support
Plate
Rail
This spec is not available in the specification table.
Connections - Terminals
Control circuit: lugs-ring terminals - external diameter: 8 mm
Power circuit: lugs-ring terminals - external diameter: 9.5 mm
This spec is not available in the specification table.
Height
77 mm
This spec is not available in the specification table.
Mechanical Durability
30 Mcycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-60…80 °C
This spec is not available in the specification table.
Electrical Durability
1.65 Mcycles 18 A AC-3 at Ue <= 440 V
1 Mcycles 32 A AC-1 at Ue <= 440 V
1.65 Mcycles 18 A AC-3e at Ue <= 440 V
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC 25...400 Hz
This spec is not available in the specification table.
[Ie] Rated Operational Current
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
This spec is not available in the specification table.
Range
TeSys
TeSys Deca
This spec is not available in the specification table.
Utilisation Category
AC-3
AC-1
AC-3e
This spec is not available in the specification table.
Motor Power Kw
4 kW at 220/230 V AC 50 Hz (AC-3)
7.5 kW at 380/400 V AC 50 Hz (AC-3)
9 kW at 415 V AC 50 Hz (AC-3)
9 kW at 440 V AC 50 Hz (AC-3)
10 kW at 500 V AC 50 Hz (AC-3)
10 kW at 660/690 V AC 50 Hz (AC-3)
4 kW at 220/230 V AC 50 Hz (AC-3e)
7.5 kW at 380/400 V AC 50 Hz (AC-3e)
9 kW at 415 V AC 50 Hz (AC-3e)
9 kW at 440 V AC 50 Hz (AC-3e)
10 kW at 500 V AC 50 Hz (AC-3e)
10 kW at 660/690 V AC 50 Hz (AC-3e)
This spec is not available in the specification table.
Protective Cover
With
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit
This spec is not available in the specification table.
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
Rated Breaking Capacity
300 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
This spec is not available in the specification table.
Average Impedance
2.5 mOhm - Ith 32 A 50 Hz for power circuit
This spec is not available in the specification table.
Power Dissipation Per Pole
2.5 W AC-1
0.8 W AC-3
0.8 W AC-3e
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Type
DC low consumption
This spec is not available in the specification table.
Coil Technology
With integral suppression device
This spec is not available in the specification table.
Control Circuit Voltage Limits
0.1...0.25 Uc (-40…70 °C):drop-out DC
0.7...1.25 Uc (-40…70 °C):operational DC
This spec is not available in the specification table.
Operating Time
77 ±15 % ms closing
25 ±20 % ms opening
This spec is not available in the specification table.
Auxiliary Contact Composition
3600 cyc/h 60 °C
This spec is not available in the specification table.
Maximum Operating Rate
1 NO + 1 NC
This spec is not available in the specification table.
Auxiliary Contacts Type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
This spec is not available in the specification table.
Minimum Switching Voltage
17 V for signalling circuit
This spec is not available in the specification table.
Minimum Switching Current
5 mA for signalling circuit
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm for signalling circuit
This spec is not available in the specification table.
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
This spec is not available in the specification table.
Climatic Withstand
conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Mechanical Robustness
Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
This spec is not available in the specification table.
Inrush Power In W
4 W (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In W
4 W at 20 °C
This spec is not available in the specification table.
Time Constant
37 ms
This spec is not available in the specification table.