Coded safety switch PSENcode, with safety switch and actuator, ATEX certificate, 8‑pin M12 male connector, series connection, long design, incl. 1 pair CABLE/M12/CLIP to secure 1 M12 plug-in connector
- Approval : CE, UKCA, cULus Listed, FCC, ATEX, IC, electrosuisse, TÜV, ECOLAB, EAC (Eurasian)
- Sensor principle : Transponder
- Coding level to ISO 14119 : Low
- Classification to EN 60947-5-3 : PDDB
- Transponder coding : coded
- Suitable for series connection : yes
- Unit type : Unit
- Supply voltage (V) : 24 V
- Type of supply voltage U1 : DC
- Power consumption DC : 1 W
- Number of inputs : 2
- DC voltage at input : 24 V DC
- Number of OSSD outputs : 2
- Number of signal outputs : 1
- Potential isolation S/C O : No
- Short circuit proof S/C output : Yes
- Utilisation category EN 60947-1 : DC-12
- ATEX certificate number : SEV 16 ATEX 0162 X
- ATEX category (gas) : II 3G Ex ec mc IIC T6 Gc
- ATEX category (dust) : II 3D Ex mc tc IIIC T80 °C Dc
- ATEX application area : -25°C ≤ ta ≤ +55°C
- Ambient temperature standard : EN 60068-2-14
- Ambient temperature : -25 – 55 °C
- Max. ambient temp. at Hmax : +55 °C
- Max. ambient temp. at 2000 m : +55 °C
- Storage temperature standard : EN 60068-2-1/-2
- Climatic suitability standard : EN 60068-2-30
- Humidity rating : 93% r.h. at 40°C
- Permitted operating height ASL : 4000 m
- EMC to standard : EN 60947-5-3
- Vibration to standard : EN 60947-5-2
- Shock resistance : 30g
- Overvoltage category : III
- Pollution degree : 3
- Protection type (housing) : IP67
- Change operating distance (temp. change) : ±0.02 mm/°C
- Type 1 actuator : PSEN cs5.13 M12 ATEX
- Sensor can be flush-mounted : Yes, follow installation guide
- Connection type : M12, 8-pin male
- Product material : PBT, PA+GF, Polycarbonate
- Height dimension : 26.4 mm
- Width dimension : 101.6 mm
- Depth dimension : 19 mm
- Net weight : 83 g
- Gross weight : 100 g
- Operating frequency : 122 kHz – 128 kHz